Mfg Part Number: 12528 | Manufacturer: Transformer Engineers Co | NSN : 6130-00-436-2659 |
Item Name : power supply | CAGE Code : 54401 | FSC : 6130 Converters Electrical Non Rotating |
MRC | Criteria | Characteristic |
---|---|---|
ABHP | OVERALL LENGTH | 6.900 INCHES NOMINAL |
ABKW | OVERALL HEIGHT | 11.630 INCHES NOMINAL |
ABMK | OVERALL WIDTH | 4.500 INCHES NOMINAL |
ADZC | ENVIRONMENTAL PROTECTION | HERMETICALLY SEALED |
ANPM | INPUT PHASE | SINGLE SINGLE OPERATING POWER RQMT |
APNX | INPUT VOLTAGE RATING | 115.0 AC VOLTS NOMINAL 2ND OPERATING POWER RQMT |
APNX | INPUT VOLTAGE RATING | 84.0 AC VOLTS NOMINAL 1ST OPERATING POWER RQMT |
APPA | OUTPUT VOLTAGE RATING | 19500.0 DC VOLTS NOMINAL SINGLE POWER OUTPUT |
APTQ | INPUT FREQUENCY RATING | 57.0 HERTZ MINIMUM 1ST OPERATING POWER RQMT AND 420.0 HERTZ MAXIMUM 1ST OPERATING POWER RQMT |
APTQ | INPUT FREQUENCY RATING | 57.0 HERTZ MINIMUM 2ND OPERATING POWER RQMT AND 420.0 HERTZ MAXIMUM 2ND OPERATING POWER RQMT |
AYNH | OPERATING AMBIENT TEMP RANGE | +0.1/+55.0 DEG CELSIUS |
CBBL | FEATURES PROVIDED | FILTER |
CWGH | OUTPUT CURRENT RATING | 100.0 DC MICROAMPERES NOMINAL SINGLE POWER OUTPUT |
FEAT | SPECIAL FEATURES | FULL RECTIFICATION |
![]() |