Mfg Part Number: CC0977-00 | Alternate P/N: CC097700 | Manufacturer: Conolog Corporation |
NSN : 5915-01-169-4091 | Item Name : filter low pass | CAGE Code : 32840 |
FSC : 5915 Filters and Networks |
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5915-01-169-4091 Item Description: Filter Low Pass | 5915 | 011694091 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
7 | A | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
Cc0977-00 | 6 | 2 | 5 |
MRC | Criteria | Characteristic |
---|---|---|
ABKW | OVERALL HEIGHT | 0.570 INCHES MAXIMUM |
ADAQ | BODY LENGTH | 1.210 INCHES MAXIMUM |
ADAT | BODY WIDTH | 1.110 INCHES MAXIMUM |
ADAU | BODY HEIGHT | 0.425 INCHES NOMINAL |
AECR | VIBRATION RESISTANCE RANGE IN HERTZ | +10.0/+500.0 |
AFGA | OPERATING TEMP RANGE | -30.0/+55.0 DEG CELSIUS |
AHAJ | REFERENCE FREQUENCY PER FUNCTION | 500.0 HERTZ BLANK |
AHAQ | SOURCE IMPEDANCE RATING PER FUNCTION | 3.69 KILOHMS BLANK |
AHAS | LOAD IMPEDANCE PER FUNCTION | 3.69 KILOHMS BLANK |
AKNA | INCLOSURE TYPE | HERMETICALLY SEALED |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 6 TERMINAL |
CQDR | INSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELS | 1.25 BLANK |
CQDW | FUNCTIONAL TERMINAL TYPE AND QUANTITY | 1 PIN INPUT 1ST FUNCTION |
CQDW | FUNCTIONAL TERMINAL TYPE AND QUANTITY | 1 PIN OUTPUT 2ND FUNCTION |
CQDW | FUNCTIONAL TERMINAL TYPE AND QUANTITY | 2 PIN GROUND 3RD FUNCTION |
CQFC | SPECIFIED FREQUENCIES OF DISCRIMINATION PER FUNCTION | 1.00 HERTZ BLANK AND 1.023 KILOHERTZ BLANK AND 1.465 KILOHERTZ BLANK AND 2.93 KILOHERTZ BLANK |
CRBB | FREQUENCY BAND WIDTH PER FUNCTION | 1.00 HERTZ BLANK AND 1.023 KILOHERTZ BLANK |
CRBC | DISCRIMINATION AT SPECIFIED FREQUENCIES PER FUNCTION IN DECIBELS | 1.5 MAXIMUM BLANK AND 1.5 MAXIMUM BLANK AND 19.0 MINIMUM BLANK AND 19.0 MINIMUM BLANK |
CRDC | MAXIMUM DIELECTRIC WITHSTANDING DC VOLTAGE | 100.0 VOLTS AT SEA LEVEL |
FEAT | SPECIAL FEATURES | 2 DUMMY TERMINALS |
PKWT | UNPACKAGED UNIT WEIGHT | 1.250 OUNCES |
STYL | STYLE DESIGNATOR | RECTANGULAR TERMINAL/TERMINALS ON ONE SURFACE |
“We Proudly Support Intrepid Fallen Heroes Fund that serves United States Military Personal experiencing the Invisible Wounds of War : Traumatic Brain Injury (TBI) and Post Traumatic Stress (PTS). Please visit website (www.fallenheroesfund.org) and help in their valiant effort”. |