Mfg Part Number: S4053 | Manufacturer: Acopian Technical Company | NSN : 6130-01-247-3956 |
Item Name : power supply assemb | CAGE Code : 14749 | FSC : 6130 Converters Electrical Non Rotating |
MRC | Criteria | Characteristic |
---|---|---|
ABHP | OVERALL LENGTH | 25.000 INCHES NOMINAL |
ABKW | OVERALL HEIGHT | 7.000 INCHES NOMINAL |
ABMK | OVERALL WIDTH | 19.000 INCHES NOMINAL |
AGAV | END ITEM IDENTIFICATION | PEACEKEEPER |
AKWC | ELECTRICAL POWER SOURCE RELATIONSHIP | OPERATING |
AMKG | POWER UNIT TYPE | SILICON CONTROLLED RECTIFIER 1ST ALTERNATE OPERATING POWER RQMT |
AMKG | POWER UNIT TYPE | SILICON CONTROLLED RECTIFIER 2ND ALTERNATE OPERATING POWER RQMT |
AMKG | POWER UNIT TYPE | SILICON CONTROLLED RECTIFIER 3RD ALTERNATE OPERATING POWER RQMT |
AMKG | POWER UNIT TYPE | SILICON CONTROLLED RECTIFIER 4TH ALTERNATE OPERATING POWER RQMT |
AMKG | POWER UNIT TYPE | SILICON CONTROLLED RECTIFIER 5TH ALTERNATE OPERATING POWER RQMT |
AMKG | POWER UNIT TYPE | SILICON CONTROLLED RECTIFIER 6TH ALTERNATE OPERATING POWER RQMT |
AMKG | POWER UNIT TYPE | SILICON CONTROLLED RECTIFIER 7TH ALTERNATE OPERATING POWER RQMT |
AMKG | POWER UNIT TYPE | SILICON CONTROLLED RECTIFIER 8TH ALTERNATE OPERATING POWER RQMT |
ANPM | INPUT PHASE | SINGLE SINGLE OPERATING POWER RQMT |
APNX | INPUT VOLTAGE RATING | 105.0 AC POUNDS PER HOUR DRY SINGLE OPERATING POWER RQMT AND 125.0 AC POUNDS PER HOUR WITH RETAINING CHAIN SINGLE OPERATING POWER RQMT |
APPA | III OUTPUT VOLTAGE RATING | 12.0 DC VOLTS NOMINAL 6TH POWER OUTPUT |
APPA | III OUTPUT VOLTAGE RATING | 15.0 DC VOLTS NOMINAL 5TH POWER OUTPUT |
APPA | III OUTPUT VOLTAGE RATING | 20.0 DC VOLTS NOMINAL 3RD POWER OUTPUT |
APPA | III OUTPUT VOLTAGE RATING | 20.0 DC VOLTS NOMINAL 4TH POWER OUTPUT |
APPA | III OUTPUT VOLTAGE RATING | 30.0 DC VOLTS NOMINAL 2ND POWER OUTPUT |
APPA | III OUTPUT VOLTAGE RATING | 5.0 DC VOLTS NOMINAL 7TH POWER OUTPUT |
APPA | III OUTPUT VOLTAGE RATING | 5.0 DC VOLTS NOMINAL 8TH POWER OUTPUT |
APPA | III OUTPUT VOLTAGE RATING | 5.0 DC VOLTS NOMINAL 9TH POWER OUTPUT |
APPA | III OUTPUT VOLTAGE RATING | 65.0 DC VOLTS NOMINAL 1ST POWER OUTPUT |
APTQ | INPUT FREQUENCY RATING | 50.0 HERTZ MINIMUM SINGLE OPERATING POWER RQMT AND 400.0 HERTZ MAXIMUM SINGLE OPERATING POWER RQMT |
AYNH | OPERATING AMBIENT TEMP RANGE | -20.0/+71.0 DEG CELSIUS |
BGQF | POWER UNIT QUANTITY | 8 |
CWGH | OUTPUT CURRENT RATING | 0.6 DC AMPERES NOMINAL 1ST POWER OUTPUT |
CWGH | OUTPUT CURRENT RATING | 0.9 DC AMPERES NOMINAL 3RD POWER OUTPUT |
CWGH | OUTPUT CURRENT RATING | 0.9 DC AMPERES NOMINAL 4TH POWER OUTPUT |
CWGH | OUTPUT CURRENT RATING | 1.2 DC AMPERES NOMINAL 6TH POWER OUTPUT |
CWGH | OUTPUT CURRENT RATING | 1.6 DC AMPERES NOMINAL 5TH POWER OUTPUT |
CWGH | OUTPUT CURRENT RATING | 12.0 DC AMPERES NOMINAL 9TH POWER OUTPUT |
CWGH | OUTPUT CURRENT RATING | 2.2 DC AMPERES NOMINAL 8TH POWER OUTPUT |
CWGH | OUTPUT CURRENT RATING | 3.0 DC AMPERES NOMINAL 2ND POWER OUTPUT |
CWGH | OUTPUT CURRENT RATING | 3.0 DC AMPERES NOMINAL 7TH POWER OUTPUT |
CWHF | OUTPUT CONNECTION QUANTITY | 2 SINGLE POWER OUTPUT |
CWHJ | OUTPUT CONNECTION TYPE | TERMINAL STRIP SINGLE POWER OUTPUT |
FEAT | SPECIAL FEATURES | THE FOLLOWING OUTPUTS ARE AVAILABLE MINUS 5.0 VOLTS AT 12.0 AMPS; MINUS5.0 VOLTS AT 2.2 AMPS; MINUS 5.0 VOLTSAT 3.0 AMPS; MINUS 12.0 VOLTS AT 1.2 AMPS; MINUS 15.0 VOLTS AT 1.6 AMPS; MINUS 20.0 VOLTS AT 0.9 AMPS; MINUS 20.0 VOLTS AT 0.9 AMPS |
![]() |
“We Proudly Support Intrepid Fallen Heroes Fund that serves United States Military Personal experiencing the Invisible Wounds of War : Traumatic Brain Injury (TBI) and Post Traumatic Stress (PTS). Please visit website (www.fallenheroesfund.org) and help in their valiant effort”. |
We Hope that You Will Visit Us Again the Next Time You Need NSN Parts and Make Us Your Strategic Purchasing Partner.
Request for Quote