Thank you for your continued interest in items we currently have available with the NSN 5945-01-186-6129 on Distribution 3Sixty. Below, you will find a comprehensive listing of all such components, including in-demand part numbers 1174028P3, RA30391051, RA3039-1-12-1, D1A12, RA30381121, and others. With utmost dedication to quality, all NSN parts in our inventory are sourced from only trusted entities around the world, and all orders are shipped to you alongside applicable manufacturer trace documentation.
Request for Quote for the required part under NSN 5945-01-186-6129 through our website and a dedicated account manager will be in touch within 15 minutes or less. . Offering rapid lead times and competitive cost savings, we only ask that you please include all information relevant to your order, such as target prices, shipping deadlines, and desired quantities. To learn more, contact us at any time via phone or email.
Item Name | Relay Reed |
Federal Supply Class (FSC) | 5945 Relays and Solenoids |
NIIN | 01-186-6129 (011866129) |
NCB Code | USA (01) |
MRC | Criteria | Characteristic |
---|---|---|
REED | ABHP | OVERALL LENGTH0 770 INCHES MAXIMUM |
REED | ABKW | OVERALL HEIGHT0 290 INCHES MAXIMUM |
REED | ABMK | OVERALL WIDTH0 300 INCHES MAXIMUM |
REED | ADZC | ENVIRONMENTAL PROTECTIONDUSTPROOF |
REED | AFJN | FRAGILITY FACTORMODERATELY RUGGED |
REED | AKDX | WINDING QUANTITY1 |
REED | AKSL | PURPOSE FOR WHICH DESIGNEDGENERAL |
REED | APCN | COIL QUANTITY1 |
REED | APNA | WINDING DC RESISTANCE RATING450 0 OHMS NOMINAL SINGLE WINDING |
REED | APNP | DUTY TYPECONTINUOUS |
REED | AXHR | MOUNTING FACILITY TYPE AND QUANTITY8 TERMINAL SINGLE MOUNTING FACILITY |
REED | BBRG | STORAGE TYPEGENERAL PURPOSE WAREHOUSE |
REED | CBBL | FEATURES PROVIDEDPOLARIZED AND COIL VOLTAGE SUPPRESSION |
REED | CRNG | NONPILE-UP MAIN CONTACT ARRANGEMENT1 POLE SINGLE THROW NORMALLY OPEN MOMENTARY ACTION |
REED | CSXF | OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP5 0 VOLTS DC 25 DEG CELSIUS SINGLE WINDING |
REED | CTDL | MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE500 0 MILLIAMPERES DC RESISTIVE LOAD |
REED | CWAB | MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS100 0 DC |
REED | CWJB | ENERGIZING ELEMENT POWER RATING50 0 MILLIWATTS |
REED | TEST | TEST DATA DOCUMENT81349-MIL-R-83516 SPECIFICATION INCLUDES ENGINEERING TYPE BULLETINS BROCHURESETC THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT EXCLUDES COMMERCIAL CATALOGS INDUSTRY DIRECTORIES AND SIMILAR TRADE PUBLICATIONS REFLECTI |
REED | TTQY | TERMINAL TYPE AND QUANTITY8 TAB SOLDER LUG ALL FUNCTIONS |
REED | ZZZK | SPECIFICATIONSTANDARD DATA81349-MIL-R-835164 GOVERNMENT SPECIFICATION |
5905-00-000-0136 (5905000000136) | 5905-00-001-2573 (5905000012573) | 5905-00-001-2813 (5905000012813) | 5905-00-001-2834 (5905000012834) |
5905-00-001-2852 (5905000012852) | 5905-00-001-2882 (5905000012882) | 5905-00-001-2890 (5905000012890) | 5905-00-001-2920 (5905000012920) |
5905-00-001-2934 (5905000012934) | 5905-00-001-2951 (5905000012951) | 5905-00-001-2952 (5905000012952) | 5905-00-001-2954 (5905000012954) |
“We Proudly Support Intrepid Fallen Heroes Fund that serves United States Military Personal experiencing the Invisible Wounds of War : Traumatic Brain Injury (TBI) and Post Traumatic Stress (PTS). Please visit website (www.fallenheroesfund.org) and help in their valiant effort”. |
We Hope that You Will Visit Us Again the Next Time You Need NSN Parts and Make Us Your Strategic Purchasing Partner.
Request for Quote