Thank you for your continued interest in items we currently have available with the NSN 5945-01-103-6240 on Distribution 3Sixty. Below, you will find a comprehensive listing of all such components, including in-demand part numbers JMAWD 26P, J412D 26WP, and others. With utmost dedication to quality, all NSN parts in our inventory are sourced from only trusted entities around the world, and all orders are shipped to you alongside applicable manufacturer trace documentation.
Request for Quote for the required part under NSN 5945-01-103-6240 through our website and a dedicated account manager will be in touch within 15 minutes or less. . Offering rapid lead times and competitive cost savings, we only ask that you please include all information relevant to your order, such as target prices, shipping deadlines, and desired quantities. To learn more, contact us at any time via phone or email.
Item Name | Relay Electromagnet |
Federal Supply Class (FSC) | 5945 Relays and Solenoids |
NIIN | 01-103-6240 (011036240) |
NCB Code | USA (01) |
Part No | Manufacturer | Item Name | QTY | RFQ |
---|---|---|---|---|
JMAWD 26P | hi g co inc | relay electromagnet | Avl | RFQ |
J412D 26WP | teledyne reynolds inc | relay electromagnet | Avl | RFQ |
MRC | Criteria | Characteristic |
---|---|---|
ABKW | OVERALL HEIGHT | 0.280 INCHES MAXIMUM |
ADAV | OVERALL DIAMETER | 0.370 INCHES MAXIMUM |
ADZC | ENVIRONMENTAL PROTECTION | HERMETIC |
AKDX | WINDING QUANTITY | 1 |
APCN | COIL QUANTITY | 1 |
APNA | WINDING DC RESISTANCE RATING | 1.56 KILOHMS NOMINAL SINGLE WINDING |
APNP | DUTY TYPE | CONTINUOUS |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 1 TERMINAL SINGLE MOUNTING FACILITY |
CBBL | FEATURES PROVIDED | COIL VOLTAGE SUPPRESSION |
CRNG | NONPILE-UP MAIN CONTACT ARRANGEMENT | 2 POLE, DOUBLE THROW, ONE POSITION MOMENTARY |
CRTL | CRITICALITY CODE JUSTIFICATION | FEAT |
CRXH | TIME DELAY | 0.002 SECONDS MAXIMUM FIXED OPERATE TIME |
CRXH | TIME DELAY | 0.004 SECONDS MAXIMUM FIXED RELEASE TIME |
CSXF | OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP | 26.5 VOLTS DC 25 DEG CELSIUS SINGLE WINDING |
CTDL | MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 1.0 AMPERES DC RESISTIVE LOAD |
CTDL | MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 100.0 MILLIAMPERES DC LAMP LOAD |
CWAB | MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | 28.0 DC |
FEAT | SPECIAL FEATURES | FAILURE RATE LEVEL 0.1 PERCENT |
TEST | TEST DATA DOCUMENT | 81349-MIL-R-39016 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTI |
TTQY | TERMINAL TYPE AND QUANTITY | 8 WIRE LEAD ALL FUNCTIONS |
ZZZK | SPECIFICATION/STANDARD DATA | 81349-MIL-R-39016/15 GOVERNMENT SPECIFICATION |
5905-00-000-0136 (5905000000136) | 5905-00-001-2573 (5905000012573) | 5905-00-001-2813 (5905000012813) | 5905-00-001-2834 (5905000012834) |
5905-00-001-2852 (5905000012852) | 5905-00-001-2882 (5905000012882) | 5905-00-001-2890 (5905000012890) | 5905-00-001-2920 (5905000012920) |